Iglewicz R, Rosenman KD, Iglewicz B, O'Leary K, Hockemeier R. Am. J. Public Health 1984; 74(5): 511-512.

Copyright

(Copyright © 1984, American Public Health Association)

DOI

unavailable

PMID

6711734

PMCID

PMC1651595

Abstract

Six hundred and ninety New Jersey ambulances were monitored for carbon monoxide (CO); 27 per cent had CO levels of 10 ppm or more greater than ambient air in the breathing zone of the patient. Twenty-nine of these ambulances had levels of at least 35 ppm greater than ambient air. Results indicate that a CO exposure problem exists in ambulances.