For monitoring and control of major hazard installations storing flammable gas, the risk based warning/early-warning is very important. A set-pair analysis (SPA) based fuzzy assessment method (SPA-fuzzy) is proposed for the real-time risk assessment in this paper. Based on principle of SPA and fuzzy logic theory, the likelihood of accident occurrence and the consequence of the accident can be assessed, and the risk value or risk degree can be evaluated. The method takes advantage of the data acquired from the real-time safety monitoring system, so that the varying of the risk can be revealed during an accident developing. The risk assessment simulation of VCE accident caused by gas leaked from LPG tank is performed. It is shown that SPA-fuzzy method has the same risk value as that assessed by normal fuzzy method.