Schaefer KE, Allison RD, Dougherty JH, Carey CR, Walker R, Yost F, Parker D. Science 1968; 162(857): 1020-1023.

Copyright

(Copyright © 1968, American Association for the Advancement of Science)

DOI

unavailable

PMID

5725383

Abstract

Data on pulmonary gas exchange were collected in breathhold dives to 90 feet in a tank and in open-sea breathhold dives to depths of 217.5 and 225 feet. Thoracic blood volume displacements were measured at depths of 25, 50, 90, and 130 feet, by use of the impedance plethysmograph. The open-sea dives were carried out with an average speed of descent of 3.95 feet per second and an average rate of ascent of 3.50 feet per second. End-dive alveolar oxygen tensions did not fall below 36 millimeters of mercury, while alveolar carbon dioxide tension did not rise above 40 millimeters of mercury except in one case. These findings indicate that for diver Croft, who has unusual lung capacity, neither hypoxia nor hypercapnia determined the depth limits under those conditions. At depths of 90 and 130 feet blood was forced into the thorax, amounting to 1047 and 850 milliliters respectively.