SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Wang X, Bao Y, Liu G, Li G, Lin L. Procedia Eng. 2012; 29: 2285-2290.

Copyright

(Copyright © 2012, Elsevier Publishing)

DOI

10.1016/j.proeng.2012.01.302

PMID

unavailable

Abstract

The alcohol concentration is usually measured through analyzing the multiple frequency absorption peak or cofrequency absorption peak of alcohol's C-H and O-H by NIRS. Based on the normalized transmittance spectrogram and Synergy interval partial least squares algorithm (SiPLS), the best analysis spectrum band detecting alcohol concentration is decided at the range of 1100nm-1330 nm and 2110nm-2400 nm or so, which is the second-harmonic peak of C-H and bending and expansion of vibration spectral section of C-H&O-H. The SiPLS model is established to analyzing 53 samples with different alcohol concentration, and obtained the root mean square error of prediction (RMSEP) is 0.0060, the correlation coefficient (R) is 0.9997, the better measuring result is obtained and this is hopeful be used to detect alcohol concentration during the Production process.