SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Berger EH, Rowland LD. J. Acoust. Soc. Am. 1989; 85(4): 1590-1594.

Affiliation

E-A-R Division, Cabot Corporation, Indianapolis, Indiana 46268-0898.

Copyright

(Copyright © 1989, American Institute of Physics)

DOI

unavailable

PMID

2708676

Abstract

The real-ear attenuation data for 81 different hearing protectors were analyzed with respect to the errors that would arise if, instead of averaging the 1/3-octave-band results at 3.15 and 4 kHz and 6.3 and 8 kHz, respectively, the octave-band attenuation at 4 and 8 kHz was estimated from only the 1/3-octave-band data at those two frequencies. Errors as large as 3-4 dB were found to occur in rare instances, but more typically were in the range of 0.5-1.5 dB. However, in terms of computation of an overall noise reduction rating such as the NRR, the effect of excluding the 3.15- and 6.3-kHz data led to errors that averaged only 0.1 dB and never exceeded 0.3 dB, except in one instance, where the error was 0.6 dB. It was concluded that there is little value in measuring real-ear attenuation in a diffuse sound field at the frequencies of 3.15 and 6.3 kHz for applications in which hearing protector attenuation data are normally utilized.