SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Gavhed DC, Holmér I. Eur. J. Appl. Physiol. Occup. Physiol. 1989; 59(1-2): 115-122.

Affiliation

Department of Work Physiology, National Institute of Occupational Health, Solna, Sweden.

Copyright

(Copyright © 1989, Holtzbrinck Springer Nature Publishing Group)

DOI

unavailable

PMID

2583139

Abstract

Twelve volunteer (VF) and 12 professional firemen (PF) wearing only brief trunks exercised on an electrically-braked cycle ergometer at three-five exercise intensities. After 45 min of exercise at 75 W, the exercise intensity was elevated in steps of 25 W every 15 min until the subject was exhausted. Air temperature was regulated to equal skin temperature (36 degrees-38 degrees C) and relative humidity was regulated at 52%. The two groups of firemen were comparable in terms of body mass, age and maximum oxygen consumption. Their oxygen consumption, rectal and skin temperatures, sweating and heart rate were measured during the tests. Blood lactate concentration was measured before, during and after the test. The physiological strain was higher in VF as indicated by higher heat storage, heart rate, skin and rectal temperatures. Sweat rate tended to be lower in VF than PF. The results indicated a better adaptation of the professional compared to the volunteer firemen to work in the heat, although the degree of heat acclimatization was considered to be equally minimal in both groups.


Language: en