SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Gallidabino M, Romolo FS, Weyermann C. Forensic Sci. Int. 2016; 272: 171-183.

Affiliation

Université de Lausanne, École des Sciences Criminelles, Bâtiment Batochime, 1015 Lausanne-Dorigny, Switzerland.

Copyright

(Copyright © 2016, Elsevier Publishing)

DOI

10.1016/j.forsciint.2016.12.027

PMID

28089301

Abstract

Estimating the time since discharge of spent cartridges can be a valuable tool in the forensic investigation of firearm-related crimes. To reach this aim, it was previously proposed that the decrease of volatile organic compounds released during discharge is monitored over time using non-destructive headspace extraction techniques. While promising results were obtained for large-calibre cartridges (e.g., shotgun shells), handgun calibres yielded unsatisfying results. In addition to the natural complexity of the specimen itself, these can also be attributed to some selective choices in the methods development. Thus, the present series of papers aimed to systematically evaluate the potential of headspace analysis to estimate the time since discharge of cartridges through the use of more comprehensive analytical and interpretative techniques. Following the comprehensive optimisation and validation of an exhaustive headspace sorptive extraction (HSSE) method in the first part of this work, the present paper addresses the application of chemometric tools in order to systematically evaluate the potential of applying headspace analysis to estimate the time since discharge of 9mm Geco cartridges. Several multivariate regression and pre-treatment methods were tested and compared to univariate models based on non-linear regression. Random forests (RF) and partial least squares (PLS) proceeded by pairwise log-ratios normalisation (PLR) showed the best results, and allowed to estimate time since discharge up to 48h of ageing and to differentiate recently fired from older cartridges (e.g., less than 5h compared to more than 1-2 days). The proposed multivariate approaches showed significant improvement compared to univariate models. The effects of storage conditions were also tested and results demonstrated that temperature, humidity and cartridge position should be taken into account when estimating the time since discharge.

Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.


Language: en

Keywords

Chemometrics; Firearm; Forensic science; Gunshot residue; Sorptive extraction; Time since discharge

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print