SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Zheng Y, Jia B, Li XG, Jiang R. Safety Sci. 2017; 92: 180-189.

Copyright

(Copyright © 2017, Elsevier Publishing)

DOI

10.1016/j.ssci.2016.10.009

PMID

unavailable

Abstract

This paper proposes an extended Floor-Field (FF) model to study the pedestrian evacuation dynamics with the influence of the fire and the smoke spreading. The spreading of smoke is from top to bottom, which leaves less and less room for the movement of pedestrians. And thus, the movement behavior of pedestrians is divided into three stages: normal walk, bent-over walk, and crawl. In the new model, the influence of the fire and the smoke on the movement of pedestrians is modeled by the fire floor field and the smoke floor field respectively. Numerical simulations are carried out to study the evacuation dynamics under fire and smoke. The influences of personnel density, fire location, exit width, fire spreading rate, and smoke spreading rate, on the evacuation efficiency are analyzed in detail. The simulation results show that the pedestrian evacuation dynamics is highly related to fire location in the room and the spreading rates of the fire and the smoke. Those results can bring some guidance to design the building structure and make the evacuation strategy in emergency situation.


Language: en

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print