Abstract

BACKGROUND: Discharging patients from emergency centers based on the clinical features of intoxication alone may be dangerous, as these may poorly correlate with ethanol measurements.

OBJECTIVE: We determined the feasibility of utilizing a hand-held breath alcohol analyzer to aid in the disposition of intoxicated trauma patients by comparing serial breathalyzer (Intoximeter, Alco-Sensor FST, St. Louis, Missouri, USA] data with clinical assessments in determining the readiness of trauma patients for discharge.

METHODS: A total of 20 legally intoxicated (LI) patients (blood alcohol concentration (BAC) >80 mg/dL) brought to our trauma center were prospectively investigated. Serial breath samples were obtained using a breathalyzer as a surrogate measure of repeated BAC. A clinical exam (nystagmus, one-leg balance, heel-toe walk) was performed prior to each breath sampling.

RESULTS: The enrollees were 85% male, age 30±10 (range 19-51), with a body mass index (BMI) of 29±7. The average initial body alcohol level (BAL) was 245±61 (range 162-370) mg/dL. Based on breath samples, the alcohol elimination rates varied from 21.5 mg/dL/hr to 45.7 mg/dL/hr (mean 28.5 mg/dL/hr). There were no significant differences in alcohol elimination rates by gender, age, or BMI. The clinical exam also varied widely among patients; only seven of 16 (44%) LI patients demonstrated horizontal nystagmus (suggesting sobriety when actually LI) and the majority of the LI patients (66%) were able to complete the balance tasks (suggesting sobriety).

CONCLUSION: Intoxicated trauma patients have an unreliable clinical sobriety exam and a wide range of alcohol elimination rates. The portable alcohol breath analyzer represents a potential option to easily and inexpensively establish legal sobriety in this population.


Language: en

Keywords

alcohol; alcohol metabolism; breathalyzer; elimination of ethanol; intoxication; trauma