SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Çelebi M, Hooper J, Klemencic R. Earthq. Spectra 2017; 33(3): 1125-1148.

Copyright

(Copyright © 2017, Earthquake Engineering Research Institute, Publisher Scitation)

DOI

10.1193/031616EQS041M

PMID

unavailable

Abstract

We analyze the recorded responses of a 64-story, instrumented, concrete core shear wall building in San Francisco, California, equipped with tuned sloshing liquid dampers (TSDs) and buckling restraining braces (BRBs). Previously, only ambient data from the 72-channel array in the building were studied (Çelebi et al. 2013). Recently, the 24 August 2014 Mw 6.0 Napa and three other earthquakes were recorded. The peak accelerations of ambient and the larger Napa earthquake responses at the basement are 0.12 cm/s/s and 5.2 cm/s/s respectively--a factor of ~42. At the 61st level, they are 0.30 cm/s/s (ambient) and 16.8 cm/s/s (Napa), respectively--a factor of ~56. Fundamental frequencies (NS ~ 0.3, EW ~ 0.27 Hz) from earthquake responses vary within an insignificant frequency band of ~0.02-0.03 Hz when compared to those from ambient data. In the absence of soil-structure interaction (SSI), these small and insignificant differences may be attributed to (1) identification errors, (2) any nonlinear behavior, and (3) shaking levels that are not large enough to activate the BRBs and TSDs to make significant shifts in frequencies and increase damping.


Language: en