SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Pap R, van Loggerenberg C. Int. J. Emerg. Med. 2019; 12(1): e15.

Affiliation

School of Clinical Medicine, University of the Witwatersrand, Johannesburg, South Africa.

Copyright

(Copyright © 2019, Holtzbrinck Springer Nature Publishing Group)

DOI

10.1186/s12245-019-0233-z

PMID

31286862

Abstract

INTRODUCTION: In the patient entrapped after a motor vehicle collision (MVC), advanced airway management may need to be performed before extrication. The aim of this study was to compare four airway management devices utilized by paramedics in a simulated entrapped patient.

METHODS: Twenty-six paramedics performed advanced airway management on a manikin seated in the driver's seat (right side) of a car. Access was through the opened door only. The airway devices were the Macintosh laryngoscope and the Airtraq optical laryngoscope to facilitate the endotracheal intubation (ETI), the laryngeal mask airway (LMA) Supreme and the laryngeal tube (LT). Time to first successful ventilation and number of attempts required for successful placement were measured. Following each placement, participants rated the degree of difficulty. For ETI, participants ranked the achieved glottic view using Cormack-Lehane grades (CLG). Finally, participants were asked which airway management device they preferred.

RESULTS: The LMA Supreme had the shortest mean time to first successful ventilation (16.7 s, CI [0.95] 14.9-18.6). Insertion of the LMA Supreme and ETI with the Macintosh laryngoscope had 100% first-attempt success. The LMA Supreme was rated least difficult to insert (mean score 1.7/10 (CI [0.95] 1.2-2.1)). Compared to the Macintosh, the Airtraq laryngoscope facilitated superior laryngoscopy (CLG I view 46.2% and 80.8%, respectively). Most participants (10/26; 38%) chose the Macintosh laryngoscope as their preferred technique, followed closely by the LMA Supreme (9/26; 35%).

CONCLUSION: The LMA Supreme took the least amount of time and was the easiest to be inserted. Extraglottic airway devices may be beneficial alternative airway management devices to be considered by paramedics in the entrapped patient. Endotracheal intubation using the Macintosh laryngoscope was performed competently by participating paramedics. The Airtraq enabled superior laryngoscopy but resulted in poorer first-pass success rate.


Language: en

Keywords

Airway management; Endotracheal intubation; Laryngeal mask airway; Traffic accidents