SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Kızılkaya E, Köse N, Ünsal Delialioğlu S, Karakaya J, Fil Balkan A. Top. Stroke Rehabil. 2023; ePub(ePub): ePub.

Copyright

(Copyright © 2023, Informa - Taylor and Francis Group)

DOI

10.1080/10749357.2023.2235800

PMID

37463033

Abstract

BACKGROUND: Patients experience falls frequently after stroke. Preserved or acquired balance skills decrease fall risk and improve independence. Feasibility of Fullerton Advanced Balance Scale (FAB) has been shown in balance assessment in some neurological diseases except stroke.

OBJECTIVES: The purpose of this study was to investigate the reliability and validity of Turkish version of FAB (FAB-T) in patients with stroke (PwS).

METHODS: This cross-sectional study included 51 PwS (60.64 ± 7.66 years). Reliability analyses were conducted with Cronbach's alpha, intraclass correlation coefficient (ICC), and Spearman correlation analysis. Intra-rater and inter-rater reliability were assessed with three raters. FAB-T, Stroke Rehabilitation Assessment of Movement (STREAM), Brunnstrom Recovery Stages (BRS), Barthel Index (BI), and 36-Item Short Form Health Survey (SF-36) were used for convergent validity. Correlations of FAB-T with Berg Balance Scale (BBS) and Mini-Balance Evaluation Systems Test (Mini-BESTest) were measured for concurrent validity. Spearman correlation analysis was used for convergent and concurrent validity. For predictive validity patients' self-reports of falling were analyzed with ROC.

RESULTS: Intra-rater (ICC = 0.998) and inter-rater reliability (ICCs = 0.984; 0.984; 0.990), and internal consistency (Cronbach's alpha = 0.930) were excellent. FAB-T had good correlations with STREAM (ρ = 0.677) and BI (ρ = 0.628), moderate correlations with BRS (ρ = 0.504 and ρ = 0.579) and physical function of SF-36 (ρ = 0.436). FAB-T excellently correlated with Mini-BESTest and BBS (ρ = 0.928 and ρ = 0.942). The cutoff score of FAB-T was determined to be 21.5 points, with sensitivity of 84% and specificity of 61% (AUC = 0.749).

CONCLUSIONS: FAB-T is a reliable and valid balance assessment tool with an acceptable accuracy of fall prediction in PwS.


Language: en

Keywords

reliability; validity; stroke; Fullerton Advanced Balance Scale; rehabilitation

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print