SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Huey RW, Buckley DS, Lerner ND. Int. J. Ind. Ergonomics 1996; 18(1): 61-69.

Copyright

(Copyright © 1996, Elsevier Publishing)

DOI

unavailable

PMID

unavailable

Abstract

This paper concerns a study aimed at selection of alarm sounds with improved audible performance characteristics for older listeners over current conventional residential smoke detectors. Many current residential smoke detectors possess alarms that have their primary frequency peak in the 4000-Hz region of the audible spectrum. Additionally, many of these alarms are constant instead of providing temporal modulation of the signal. This study analyzed a variety of alternative sounds for selection as a better choice for an 'age-sensitive' smoke alarm signal. The study presented a battery of candidate sounds to pairs of subjects aged 65 years and older with varying levels of hearing impairment (0-45 dB) in their own homes to see which sounds performed best in terms of detection, localization, and perceived attention-getting value. Subjects were placed in various location- and masking-based conditions within their homes during listening periods and subjected to sounds played at a constant level. A computerized system collected response data as the battery of stimuli was presented. The data showed a fairly predictable positive trend in detection and localization performance level as the frequency of the stimuli decreased from 4000 to 500 Hz. The data also showed that pulsed signals were more detectable than steady alarms.

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print