SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Gao R, Li A, Lei W, Zhao Y, Zhang Y, Deng B. Safety Sci. 2012; 50(7): 1549-1557.

Copyright

(Copyright © 2012, Elsevier Publishing)

DOI

10.1016/j.ssci.2012.03.007

PMID

unavailable

Abstract

Subway tunnel fires often result in catastrophes and heavy casualties. To help people evacuate from a tunnel fire, an opposite-double air curtain ventilation assisted tunnel evacuation system (OTES) is introduced. It can be used to create a safe evacuation passageway that is free of smoke through out the length of the tunnel. The performance of the OTES is compared with that of the traditional ventilation systems: longitudinal ventilation and natural ventilation. The effect of the heat release rate, fire source location, and fire detection time are also discussed.

This study also shows that compared with natural ventilation and longitudinal ventilation, the carbon monoxide, CO, concentration with OTES is significantly lower. Given the same HRR, the CO concentration values with OTES are only 0.58-2.41% of natural ventilation or 0.52-3.12% of longitudinal ventilation at the back end of the tunnel. An obviously clear evacuation passageway is created by OTES. The effects of changes in fire source location and fire detection time on tunnel ventilation are tested. Also the effect of these changes on the formation of an evacuation passageway by OTES is reported.

NEW SEARCH


All SafetyLit records are available for automatic download to Zotero & Mendeley
Print